Page 8 - Voice & Visual Communication Solutiions Catalog
P. 8

Analog Page Controls
    8











        A                  B            C            D               E          F           G        H
         Analog
                                                                       Analog
         2000 Series                                                Page Controls

                             ™
                                                        VPU                                                        VPU
      A  1 Zone   uns                                               PBX Loop Start Trunk, Electronic Key Line, Single Line Phone
         •  Basic Zone or Area of Paging                         E
         One-Way. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V-2000A   1 Zone u
         2.60”H x 7.70”W x 5.30”D  (6.60cm x 19.56cm x 13.46cm)  2.6lbs (1.2kg)  Talkback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V-9941A
                                                                    8.25”H x 4.65”W x 2.30”D  (20.96cm x 11.81cm x 5.84cm)  1.5lbs (0.68kg)
      B  1 Zone Enhanced   uns
         •  Phantom Zone™ Allows Paging to All Speakers But Limits Music    Station Level/FXS Adapters
           to Selected Speakers                                     1 Zone l
         One-Way. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V-2001A
         One-Way European Version*. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V-2001A-E   F  For use with One-Way Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V-9970
                                                                    8.25”H x 4.50”W x 2.35”D  (20.96cm x 11.43cm x 5.97cm)  1.5lbs (0.68kg)
         7.10”H x 9.00”W x 2.40”D  (18.03cm x 22.86cm x 6.10cm)  3.7lbs (1.68kg)   G
         *International Version - Power Requirements:  230 Vac/.5A  For use with One-Way or Talkback Controllers. . . . . . . . . . . . . . .V-9940
                                                                    8.20”H x 4.55”W x 2.30”D  (20.83cm x 11.56cm x 5.84cm)  1.7lbs (0.77kg)
      C  3 Zones   uns                                           H  PagePal Interface unsl  .......................................V-5335700
         •  Three Zones of One-Way Paging Plus All Call             2.50”H x 6.00”W x 4.00”D  (6.35cm x 15.24cm x 10.16cm)  2.0lbs (0.91kg)
         One-Way. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V-2003A
         7.10”H x 10.00”W x 3.00”D  (18.03cm x 25.40cm x 7.62cm)  4.1lbs (1.86kg)
         One-Way European Version*. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V-2003A-E
         7.10”H x 10.00”W x 3.00”D  (18.16cm x 25.40cm x 7.62cm)  4.1lbs (1.86kg)
         Talkback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V-2003AHF
         7.10”H x 10.00”W x 3.00”D  (18.03cm x 25.40cm x 7.62cm)  5.6lbs (2.54kg)  What is a Zone?
         Talkback European Version* ................................. V-2003AHF-E   A zone can be any area, any size that you determine.
         7.10”H x 10.00”W x 3.00”D  (18.16cm x 25.40cm x 7.62cm)  5.6lbs (2.54kg)   It's usually an area where the same overhead pages would need to be heard.
         *International Version - Power Requirements:  230 Vac/.5A
                                                                  Within a zone you can have as many different types of speakers as you want.
      D  6 Zones   uns                                            From basic overhead round ceiling speakers, to high-fidelity sound, to horns for
         •  Six Zones of One-Way Paging, All Call, 3 Programmable Zone Groups  water-proof areas, to door entry speakers and many more.
         One-Way. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V-2006A
         10.90”H x 13.00”W x 2.70”D  (27.69cm x 33.20cm x 6.86cm)  6.2lbs (2.81kg)
         One-Way European Version*. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V-2006A-E
         10.90”H x 13.00”W x 2.70”D  (27.69cm x 33.20cm x 6.86cm)  6.2lbs (2.81kg)
         Talkback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V-2006AHF
         10.90”H x 13.00”W x 2.70”D  (27.69cm x 33.20cm x 6.86cm)  7.5lbs (3.40kg)
         Talkback European Version* ................................. V-2006AHF-E
         10.90”H x 13.00”W x 2.70”D  (27.69cm x 33.20cm x 6.86cm)  7.5lbs (3.40kg)
         *International Version - Power Requirements:  230 Vac/1.0A

                                                                         One-Way Page Controls   Talkback Page Controls
      Step 1 Select a Page Control                                  V-2000A  V-2001A  V-2003A  V-2006A  V-2003AHF  V-2006AHF
                                                      Number of Zones  1     1      3       6       3        6
      Easy Selection                                   Background Music  •    •      •      •       •         •
      Considerations:                                         All Call  •     •      •      •       •         •
                                                           Group Call
      • Number of  Zones          Features         Emergency Page Override         •    •   • •       •       • •
      • One-Way Broadcast Only                   Night Ring/Time Clock Tones     •   •      •       •         •
         or                                      Valcom Power Units Provided  + 12  + 20  + 20  + 30  + 10  + 20
         Talkback (Includes One-Way)
                                             PBX Loop Start Trunk Port
         Two-Way HandsFree                  Electronic Key Line Position      •      •      •      •      •      •
                                  Telephone Access  Audio   FXO  Port  PBX Ground Start Trunk Port  n n     •      •      •     •     •     •
      • Special Features             FXO    Dedicated Single Line Phone Set  u u              •    •     •     •
                                                      Page Port
                                            (Telephone System Dependant) s s
                                                Centrex or C.O. Line
                Look for these orange symbols   FXS  PBX Analog Station Port   l l  Use V-9970   Use V-9970   Add V-9940
                when selecting page controls  (Loop Disconnect Required)
                                                       I
                                            1.540.563.2000   1.800.VALCOM-1 (1.800.825.2661)